Ciena 3928 configuration guide. pre-made ones from CienaAs you are onboarding to Ciena devices I will suggest you start from the Videos Section of the community. Ciena 3928 configuration guide

 
 pre-made ones from CienaAs you are onboarding to Ciena devices I will suggest you start from the Videos Section of the communityCiena 3928 configuration guide  Customer Benefits Ciena’s 3903 provides a single-box solution for access, service delivery, and in-depth management

The 3924 features a high-capacity 44 Gb/s switching fabric supporting four 10GbE/1GbE ports and four 1GbE ports in a compact 1RU chassis. Number of Views 4. Number of Views 4. terminal length 0 terminal width 512 show inventory raw show version show ethernet service instance detail show ip as-path-access-list show ip bgp neighbors show ip route static show ip route 0. Number of Views 4. After examining Adv Enet Config guide for SAOS, I am confused regarding port VLAN, port. interface create ip-interface VC VC1 ip X. If you have access to the Ciena Portal, then you should be able to access the configuration guides for any Ciena products which will have sample configurations. By continuing, we assume that you consent to receive all cookies on all Ciena websites. CLI Configuration Guide for CN 3928 Hi, I need CLI Guide document for CN 3928 Regards, Raja 3928 3900 Family Upvote Answer Share 3 answers 2. Number of Views 4. oc-if:interfaces interface mgmtbr0 ipv4 addresses address 10. SAOS 8. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. Bankruptcy Code and requires Ciena's consent to any assignment related to a bankruptcy proceeding. By continuing, we assume that you consent to receive all cookies on all Ciena websites. One Cisco interface only transmits but not receives. 255 longer-prefixes show ip route connected show. MCP: How to restart a single container to clear its alert in Nagios. Kind of at a stand still. Expand Post. virtual-switch ethernet create vs vs-ciena-mgmt-1130 encap-fixed-dot1dpri 7 vc vc-ciena-mgmt-1130. 0 Software Configuration Guide 1. Number of Views 4. 2K how do I obtain proper console cable db-9 to rj-45 cable for the console. The 3928 needs to reserve a port in order to have the hardware resources to run benchmark tests. By continuing, we assume that you consent to receive all cookies on all Ciena websites. 3903 Platform. User : su . Regards, Fadil. The documentation set for this product strives to use bias-free language. The small, slim design enables deployment in a variety of indoor environments determined by end-user circumstances, while delivering the small footprint and low noise characteristics. 12 the reserved port is beyond me on the CN3928. Ciena reserves to itself and its licensors all rights in the Software andHi Chelsi, command-log show, I see is a very useful command, but this only lists what commands were last issued. 17. 99> secret <yoursecret>" I've confirmed that RADIUS is configured via the. 21K I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. Ciena’s 5130 Router is purpose-built for 5G networks that converge 4G/5G fronthaul, midhaul, and backhaul (xHaul) networks onto a common, simpler infrastructureHas anyone ever seen an XC card constantly doing a "configuration search string" command on its own over and over? This is happening right now in my netowork. I am wanting to know if I can use the MGMT port on the 5164 for Out-Of-Band Management to the 5164 and other devices connected to that 5164. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial. For example, right now we have a 3902 at a customer prem connected to a 5150. The compact, cost-effective open network edge platform is powered by a built-in simplex AC power supply and designed to fit two 3924s in a single rack, to support a variety of deployments. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on. Command. 3928. 3903 Platform. Software Upgrade, License Activation and Nodal AT Ciena 3928. By continuing, we assume that you consent to receive all cookies on all Ciena websites. Features industry-leading 10GE density in a non-blocking, wire-speed architecture with 24 10GE/1GE multi-rate SFP+ ports. 3928> configure <TAB> show save. Number of Views 4. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Upvote Upvoted Remove. Bankruptcy Code and requires Ciena's consent to any assignment related to a bankruptcy proceeding. Console port on a 5170. Selected as Best Selected as Best Upvote Upvoted Remove Upvote. Stacey P1 (Customer) asked a question. David G28 (Customer) asked a question. 48K. Enables dual-homed or ring-based topologies for highly reliable MEF CE2. 16. The available reporting API calls support the generation of the following reports: ALARMS_REPORT: Provides current alarms present in the network. 135. 77K. Sole title to the Software and documentation, to any derivative works, and to any associated patents and copyrights, remains with Ciena or its licensors. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on. cfm service enable service HNVL-TRIGGER-WEST. pre-made ones from CienaWe have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. By continuing, we assume that you consent to receive all cookies on all Ciena websites. We are looking for how to disable/discard STP on each port Ciena Device 3930 an 5142. I called technical support, but they could not find our service agreement. Global parameter list. 255. 5142 Side: cfm service create vlan 3901 name HNVL-TRIGGER-WEST md md1 ma-name-format vid ma-name-vid 3901. In a redundant OSPF GNE configuration, Do we allow inter OSPF domain routing for managing nodes via GNEs of other OSPF areas ? and if yes, how do we do it in 6500 OME ?. S. From 1. Upvote Upvoted Remove. 19K how do I obtain proper console cable db-9 to rj-45 cable for the console. The compact, open, network edge platform is powered by an. 0 “under Network & sharing Center >>change adopter. I am on SAOS 06-19-00-0277 on a Ciena 3928. After examining Adv Enet Config guide for SAOS, I am confused regarding port VLAN,. To consent to receive all cookies on all Ciena websites, click I acknowledge. Number of Views 4. Ciena is a global leader in optical and routing systems, services, and automation software. Global parameter list. example: vlan create vlan 4070. Generator Configuration: benchmark create generator name. Thank you. 0 255. To consent to receive all cookies on all Ciena websites, click I acknowledge. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. Answer. Routing and Switching; Upvote; Answer; Share; 4 answers; 139 viewsWe have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. 3928> config sh br. Routing and Switching. 3928 Service Aggregation Platform Installation and Startup. It is also based on SAOS. How reliable is NETCONF for configuration management for SAOS6 devices? Considering using it in production but there appears to be very little documentation or discussion of it here on the Ciena portal, community, and internet. PM stats can be enabled on flow-points & IP interfaces on the device. planning guide. 17. Number of Views 2. 19. Funcionality. Ciena and the Ciena Logo are trademarks or registered. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. This enables one to perform service assurance and stats collection on those endpoints. The documentation leads me to believe that port 7 is the only port that can be used on the 3928 to enable benchmark tests, similar to how port 20 is the only port that can be used on the 5160. The 5400 uses #6, #4, or #2 AWG depending on the system configuration. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. RLS: (Master) OTDR Traces, Settings, & Troubleshooting. Sustainability Support Services. 1 can ping the ciena IPs 255. The 3902 has customer port untagged, pvid 123 and vlan 123 is on ports 1 and 2. 19K How do I pull the serial number from devices using SNMP polling?2. The 3928 needs to reserve a port in order to have the hardware resources to run benchmark tests. Ciena’s 5166 Router is purpose-built for 5G networks that converge 4G/5G fronthaul, midhaul, and backhaul (xHaul) networks onto a common, simpler infrastructure. Number of Views 4. All NE's LOA in OneControl GUI but are in 'completed' state in Manager for 6k,OM5K and CPL. If the slot configuration mode is derived (check Photonic Configuration Management for the OTS in question) you can't delete MLA from the slot sequence / remove the ADJs without the reconfig mode no matter if its a non-DOC site or not. 17K how do I obtain proper console cable db-9 to rj-45 cable for the console. We have ciena 3928 and i couldn't console via putty after i gave all the relevant. With dense 1/10/25GbE to 100/200GbE aggregation and support for both hard network slicing (FlexEthernet) and soft network slicing (Segment Routing), the temperature-hardened. 6 Tb/s performance optics and 400G coherent pluggables to compact ROADMs and control plane automation, Ciena’s 6500 Family of Packet-Optical Platforms enables you to continually stay ahead of customer demands. 233. Portal Explore 3924 Ciena’s 3924 Platform is purpose-built for 10 Gb/s service delivery in a variety of business or mobile backhaul environments. Ciena Operational Commands. Offers dual hot-swappable AC or DC power in a high-availability, temperature-hardened, 1RU package. The 3922 features a cost-effective 24 Gb/s switching fabric capacity, supporting two 1/10GbE and two 100M/1GbE fiber ports, and two 10M/100M/1GbE copper ports. 3928> _ To view the CONSOLE serial interface information. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. 17. To consent to receive all cookies on all Ciena websites, click I acknowledge. Bankruptcy Code and requires Ciena's consent to any assignment related to a bankruptcy proceeding. Then locate the product and SAOS version. Below is configuration which i used to configure IP interface and static routes on each device: ##### #Device A:. CLI command to look at the MAC address table on a particular VLAN. Technical questions regarding the Ciena 3903 and 3924. Number of Views 4. I am wanting to know if I can use the MGMT port on the 5164 for Out-Of-Band Management to the 5164 and other devices connected to that 5164. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Example: CN5130> config backup filename CN5130_backup_05_April_2022. you can use same for 5142. Network Element should not be allocated with any SID value. Ciena’s 3928 Platform is a cost-effective solution for 10 Gb/s service delivery in a variety of business or mobile backhaul environments. 3928> configure <TAB> show save. By continuing, we assume that you consent to receive all cookies on all Ciena websites. The 3928 features a high-capacity 48 Gb/s switching fabric supporting four 1GbE or 10GbE ports and 8 100/100M/1000M ports in a compact 1RU chassis. Ciena’s 3924 Platform is purpose-built for 10 Gb/s service delivery in a variety of business or mobile backhaul environments. Number of Views 4. I am trying to find a way if I placed hard loopback on (3928-B port 1) and test from 3928-A to that loopback that is on 3928-B port 1. Ciena’s 3928 Service Delivery Switch is a cost-effective platform for 10 Gb/s Ethernet service delivery in a variety of business or mobile backhaul environments. Step 1: To take the backup of device running configuration and save into a file, run below CLI command in user mode : CN5130> config backup filename <file-name>. Number of Views 4. Number of Views 4. I have the mgmtbr0 configured with an IP address and have that port directly connected to a Juniper ACX. Traffic-profiling can be done port based or vlan based. pre-made ones from CienaIs it possible to use simultaneously the following ports on the new Flex MOTR NTK538FR (to reach a total 248G capa usable, going through DWDM Line interface) :Configuration CIENA Router Series 8180,5171,3926,5142,5160,3928. Password: Waiting for authentication server reply - I tried below username and password ,still the same issue. S. What do OCI and OCLD stand for? Number of Views 3. 323-4001-100 user guide had the references. We have ciena 3928 and i couldn't console via putty after i gave all the. performance metrics available for end-customer SLA reporting. View and Download Ciena CN 3960 hardware installation manual online. Instead of add/drop the 10G client, I want to add/drop as OTU4 using NTK529HA. Ciena® cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or access. 3801 XGS-PON Optical Network Unit. 3928. MCP & INOC, SDH & E1 Service configuration. We would like to show you a description here but the site won’t allow us. This seems to be reserving an over abundance of network addresses. x: Manual CTX switchover causes all LM modules to reboot. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. This was a big gotcha on the 5160, glad to see Ciena has kept. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. 39K. 14. 19K how do I obtain proper console cable db-9 to rj-45 cable for the console. ac. MCP5. 6500 RLS License Violation and External License Server Comms Failed. 68K CLI command to look at the MAC address table on a particular VLAN. After examining Adv Enet Config guide for SAOS, I am confused regarding port VLAN,. Hi @Muhammad Syahrul F (Customer) Below are the commands line to disable the STP. X. 2K what is difference between in wss and ccmd card. Contacting Ciena For additional office locations and phone numbers, please visit the Ciena web site at Corporate Headquarters 410-694-5700 or 800-921-1144 Customer Technical Support. Number of Views 4. performance metrics available for end-customer SLA reporting. 2 6500 RA logs can result in 6500 management issues. Number of Views 4. Can't find a good configuration guide on the Ciena side to actually enable this via CLI on the 3928, Any help/links/anything would be. The SONET/SDH services must be tolerated by MCP. Number of Views 4. snmp vacm group public member public security-model v2c. To consent to receive all cookies on all Ciena websites, click I acknowledge. Now, we suddenly need to install these devices and configure a 100G service for one of our customers. Expand Post. 3. To consent to receive all cookies on all Ciena websites, click I acknowledge. We usually perform RFC test and the way I place a loop at the Ciena is by issuing the command : port set port 1 loopback on. a. 6500 PTS with subring configuration Does 6500 PTS(NTK614AA/fabric and Ntk695aa/interface) support 2. Hi @NNAJI O (Customer) Here's one point I found in the Waveserver User guide regarding maintenance:. Below the capture example port on our Ciena device. 16K how do I obtain proper console cable db-9 to rj-45 cable for the console. Ciena’s 3928 Platform is a cost-effective solution for Features and Benefits. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. ATA S H E E T 3928 Ciena’s 3928 Platform is a cost-efective solution for 10 Gb/s service delivery in a variety of business or mobile backhaul environments. To start provisioning sections of the Ciena via CLI, you will enter the command with various sub-commands. Number of Views 1. Not sure how the EERO device "calls home," but I suspect it is via URL that needs to be resolved. 365 of the U. pre-made ones from CienaWe have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. All the LEDs on the faceplate will be lit, then they will flash to indicate that the hard reset has been initiated. There are two interfaces in a active/active LACP configuration in each port-channel between the two. 0. By continuing, we assume that you consent to receive all cookies on all Ciena websites. Bias-Free Language. To log out of the. Section 365 of the U. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. 5G and 1G subring configuration is supported from quite old release, but to confirm about MPLS I would like to know your working software release on the NE. The unit is powered by fixed, dual AC or DC power supplies, and is supported in environments requiring extended temperatures (DC option) such as outdoor cabinets or other uncontrolled environments. Cisco Nexus 5000 Series Switch CLI Software Configuration Guide Chapter31. I have this line in my config/brief that I need to get rid of to default the port, but cannot work out how to get it back to basics: port set port 21 acceptable-frame-type all pvid 313 egress-untag-vlan 313. To consent to receive all cookies on all Ciena websites, click I acknowledge. 6K Where can I find a configuration guide/document that states how to authenicate the 6500 & 8700 to Cisco ISE using tacacs+. 3928 1; 5160 0; Ciena uses cookies to ensure that we give you the best experience when visiting. This question is closed. Number of Views 4. 21K how do I obtain proper console cable db-9 to rj-45 cable for the console. Converged Packet Optical. After examining Adv Enet Config guide for SAOS, I am confused. Can I get a little clarification? Does the 3924 really have that level of grounding requirements? Expand Post. 87K. Ciena’s 3928 Platform is a cost-effective solution for 10 Gb/s service delivery in a variety of business or mobile backhaul environments. cfm mep create service HNVL-TRIGGER-WEST port 24 type down mepid 1. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. To consent to receive all cookies on all Ciena websites, click I acknowledge. 3928. Since the cisco 3900 has reached end of life we are hoping that it is possible to remove the Cisco device and simpilfy our HA cluster. how it works ? i want to know about this cards ?I have NTK538BJ. 2. CN390_0061_5A> rstp disable port 1-10. This was a big gotcha on the 5160, glad to see Ciena has kept this great feature going. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. CN3930_0061_5A> mstp disable. Any guidance is appreciated. a. HarshitaI am on SAOS 06-19-00-0277 on a Ciena 3928. The 3930 incorporates a complete Operations, Administration, and Maintenance (OAM) [2] SAOS 6. Not sure how the EERO device "calls home," but I suspect it is via URL that needs to be resolved. 22K how do I obtain proper console cable db-9 to rj-45 cable for the console. Selected as Best Selected as Best Upvote Upvoted Remove Upvote. Hi @Oleg V1 (Customer) , to add to @Amit G1 (Customer) 's response, I'd also ask your Ciena account team to give you access to Product Communications (located here in myCiena) and sign you up for email notifications. Number of Views 4. Features and benefits. Customer Benefits Ciena’s 3903 provides a single-box solution for access, service delivery, and in-depth management. To consent to receive all cookies on all Ciena websites, click I acknowledge. Hi, I have a question regarding running an RFC test thru a port loop on the Ciena. Hi, We have ciena 3928 and i couldn't console via. I would like to renumber the nodes and as soon as I delete the OSPF circuit from the shelf, I will lose comms to it. @Paolo E (Customer) Thanks for reaching to ciena community. ciena. 08K I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. I am able to ping the device over the command line, but no configuration shows up in either Terra term nor the Command Prompt. Commissioning with the support of NOC team Ciena 3928. 02K. Ciena’s 3903x Service Delivery Switch is an advanced Ethernet business demarcation device in a cost-effective and compact form factor. pre-made ones from CienaHello, is there a way to make the Ciena automatically rollback config unless we confirm the changes made? For example, I'm remotely connected to the Ciena and I want to try changing the network port to 1Gb full duplex with auto neg on. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. I would like to add another one in Standby/Backup and to configure the chassis with configuration 1+1 protected. Incorporates on-board RFC 2544 Performance Benchmark. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. The unit is powered by fixed, dual. Number of Views 2. To consent to receive all cookies on all Ciena websites, click I acknowledge. Can't find a good configuration guide on the Ciena side to actually enable this via CLI on the 3928, Any help/links/anything would be. 48K. Expand Post. The fact you can't make ports 1. Ciena’s 3928 Platform is a cost-effective solution for 10 Gb/s service delivery in a variety of business or mobile backhaul environments. Number of Views 4. By continuing, we assume that you consent to receive all cookies on all Ciena websites. 95K How do I pull the serial number from devices using SNMP polling?Ciena’s 3903 Platform provides a single-box solution for access, service delivery, and in-depth management. 3928> _. March 22, 2022 at 10:35 PM. By continuing, we assume that you consent to receive all cookies on all Ciena websites. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. How to configure MGMT port on a Ciena 5130 running software version Saos10. 19K How do I pull the serial number from devices using SNMP polling?RFC2544 reflector configuration on a NTK667AA and NTK616BA. pre-made ones from CienaMCP presence of pre-5. 21K I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. The 5400 uses #6, #4, or #2 AWG depending on the system. By continuing, we assume that you consent to receive all cookies on all Ciena websites. From 1. We build the world’s most adaptive networks to address ever-increasing digital demands for richer, more connected experiences for all users. 21K How do I pull the serial number from devices using SNMP polling?We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. By continuing, we assume that you consent to receive all cookies on all Ciena websites. The configuration is: OTU4 QPSK < -- > NTK538BJ x NTK529HA < -- > OTU4 client. Funcionality. So i have tried this: dhcp-client client mgmtbr0 admin-enable false. Step 1: Power on the Device and verify that all LED are blinking green. 3928> user lockout-policy show. mac show. Here's what is in the Advanced OAM Configuration guide for SAOS 6. The TOE is a family of standalone network hardware appliances that run the Ciena Service Aware Operating System (SAOS) 6. To consent to receive all cookies on all Ciena websites, click I acknowledge. 1. 6. Ciena is a global leader in optical and routing systems, services, and automation software. I cannot find anything in the "Data Communications Planning and User Guide" 323-1851-101 guide. We can telnet from SAOS 10. We are gearing up to install MCP and I'm reading through the Engineering Guide from March 2021 (the latest I could find) and this looks to be requiring a beast of a VM. pre-made ones from CienaWe have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Number of Views 4. 3801 XGS-PON Optical Network Unit. no service pad. 73K. 2 6500 RA logs can result in 6500 management issues. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Can't find a good configuration guide on the Ciena side to actually enable this via CLI on the 3928, Any help/links/anything would be. 10 Gb/s service delivery in a variety of business or • Offers 48 Gb/s of non-blocking. The 3928 features a. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Type : 100GBASE-SR4 MPO QSFP28 transceiver installed at client interface 5, 6, 7, or 8, this attribute is enabled by default. Thanks again for getting back to me. Any input or suggestion would be much appreciated!The section on port mirroring is in chapter 14 of the Advanced Ethernet Configuration Guide. admin, for making significant system state changes, modifying the system configuration, and performing execute commands. password : wwp. 19K I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. Port. X. Thanks! SuthaWe have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. 3928> user username-policy show # 3928> user set user su echoless. Number of Views 4. To consent to receive all cookies on all Ciena websites, click I acknowledge. x software then you can use "base_advance_ethernet_and_oam_configuration" file for ethernet and oam related. Harnessing Ciena’s WaveLogic Ai coherent optical technology, Waveserver Ai offers the scalability required to satisfy the largest interconnect requirements, from metro to ultra-long-haul distances. I have a series of technical questions regarding the Ciena 39xx series (namely the 3903 and 3924) that I need to have answered. vlan add vlan 4700 port 1. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. 365 of the U. FEC is by default disabled for Line ports & it is by design, it cannot be enabled. 12 the reserved port is beyond me on the CN3928. 6 or 8. MCP presence of pre-5. This was a big gotcha on the 5160, glad to see Ciena has kept this great feature going. Loading of the configuration files varies depending on the size of the configuration files. Supports 4 GbE NNI/UNI ports including 2 100/1000 Base-X SFP ports and 2 dual-mode ports: RJ-45 10/100/1000 Base-T and 100/1000 Base-X SFPs. 3928> user acct show. pre-made ones from CienaI have configured a primary RADIUS server on our Z-series nodes following the procedure in the Z-series Engineering and Planning Guide. you can choose the file. Number of Views 4. The 3948 addresses customers’ key needs, supporting routing, Multi-Protocol. Number of Views 4. Using a fiber connection to the 3928 located at a customer location I am looking for 'Best Practice' methods for setting up in-band management. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. cfm service enable service HNVL-TRIGGER-WEST. I am on SAOS 06-19-00-0277 on a Ciena 3928. I am able to ping the device over the command line, but no configuration shows up in either Terra term nor the Command Prompt. Purpose-built to fit sites of all sizes and types with support for Passive Optical Networks (PONs), TDM, Ethernet, Multi-Protocol Label Switching (MPLS), IP, and virtual network services. The 3903x is based on Ciena’s field-proven Carrier Ethernet technology, which has been deployed worldwide by dozens of network operators. 3802 XGS-PON Optical Network Unit. Loading of the configuration files varies depending on the size of the configuration files. vlan remove vlan 127 port 9. CLI command to look at the MAC address table on a particular VLAN. License Server: load license fails after Registered Server transferred from one account to another in Ciena Portal. It means that the license is not valid or, to enable it I need to run some command on the cli ? SW Package: Slot 1 - saos-06-21-00-0091. I tried to use putty with serial port to login CIENA 3930 to load configuration, I can't talk to CIENA, it didn't sho… Number of Views 1. Check out the entries in the configuration guide for those two and see if they will suit your needs. MCP: Policy management for updating license server on network elements. 14, with uniform security functionality between each of the hardware appliances. Has anyone ever seen an XC card constantly doing a "configuration search string" command on its own over and over? This is happening right now in my netowork. I tried to use putty with serial port to login CIENA 3930 to load configuration, I can't talk to CIENA, it didn't sho…. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial. 3928. Z-Series: NTP setup or alarm. After examining Adv Enet Config guide for SAOS, I am confused regarding port VLAN,. STEP 1 : Ask Field engineer to put IP: 172.